J Clin Pharmacol
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     

Sign In to gain access to subscriptions and/or personal tools.
First published on August 20, 2008, doi:10.1177/0091270008322911

The Journal of Clinical Pharmacology 2008;48:1189.

This Article
Right arrow Full Text (JCP OnlineFirst[PDF])
Right arrow All Versions of this Article:
0091270008322911v1
48/10/1189    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kuczka, K.
Right arrow Articles by Blume, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kuczka, K.
Right arrow Articles by Blume, H.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?
©© 2008 American College of Clinical Pharmacology, Inc.
The Journal of Clinical Pharmacology, 10.1177/0091270008322911


Article

Biomarkers and Coagulation Tests for Assessing the Biosimilarity of a Generic Low-Molecular-Weight Heparin: Results of a Study in Healthy Subjects With Enoxaparin

Karina Kuczka 1, Sebastian Harder 1*, Bettina Picard-Willems 1, André Warnke 2, Frank Donath 2, Pietro Bianchini 3, Bruna Parma 3, and Henning Blume 2

1 Institute for Clinical Pharmacology, University Hospital Frankfurt, Germany
2 SocraTec R&D GmbH
3 OPOCRIN S.p.A.

* To whom correspondence should be addressed. E-mail: harder{at}em.uni-frankfurt.de.


   Abstract
Low-molecular-weight heparins (LMWHs) differ considerably in their influence on clotting tests and release of tissue factor pathway inhibitor (TFPI). Biosimilarity therefore becomes an issue when generic forms of LMWHs are developed. So far, no bioequivalence study with a generic LMWH has been reported. A generic enoxaparin (test) was compared with the originator (reference) in 20 volunteers after single-dose subcutaneous administration (40 mg enoxaparin sodium, 4000 IU/mL anti–factor Xa (anti-FXa; activity). Target variables were anti-FXa and anti-FIIa activity, activated partial thromboplastin time (aPTT), prothrombinase-induced clotting time (PiCT), and TFPI over 24 hours. The statistical evaluation of the anti-FXa activity profile demonstrated bioequivalence of test and reference with confidence intervals of area under the plasma concentration-time curve (AUC0-tlast) (93%-99%) and Amax (88%-95%). Confidence intervals of AUC0-tlast (89%102%) and Amax (90%-103%) of anti-FIIa activity also fulfill bioequivalence criteria. The 90% confidence interval for the maximum concentration of TFPI ranged from 90% to 113%. The claim of similarity was also supported by aPTT and PiCT profiles. Bioequivalence with the originator enoxaparin could be demonstrated by ex vivo inhibition of FXa and FIIa activity, by coagulation tests (aPTT and PiCT), and by in vivo release of TFPI. Whether such data also prove biosimilarity of the generic enoxaparin needs to be determined.