J Clin Pharmacol
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     

Sign In to gain access to subscriptions and/or personal tools.
First published on January 31, 2008, doi:10.1177/0091270007311572

The Journal of Clinical Pharmacology 2008;48:436.

This Article
Right arrow Full Text (JCP OnlineFirst[PDF])
Right arrow All Versions of this Article:
0091270007311572v1
48/4/436    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lehmann, C.
Right arrow Articles by Wannarka, G. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lehmann, C.
Right arrow Articles by Wannarka, G. L.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?
©© 2008 American College of Clinical Pharmacology, Inc.
The Journal of Clinical Pharmacology , 10.1177/0091270007311572


Article

Bioavailability and Dose Proportionality of Intramuscular Diazepam Administered by Autoinjector

Craig Lehmann 1* and Gerald L. Wannarka 2

1 August Consulting, Inc
2 Meridian Medical Technologies

* To whom correspondence should be addressed. E-mail: clehmann{at}august-consulting.com.


   Abstract
A diazepam 10-mg autoinjector was evaluated in bioequivalence and dose proportionality studies; both involved 24 young, healthy subjects and used randomized, open-label, 2-treatment, 2-period crossover designs with a 3-week washout period between treatments. The bioequivalence study compared a single diazepam 10-mg autoinjector with a conventional needle and syringe containing 10 mg of diazepam injectable. The dose proportionality study compared the pharmacokinetics of a single diazepam 10-mg autoinjector with that of 2 diazepam 10-mg autoinjectors given simultaneously (20 mg). Injections were intramuscular in the midanterolateral thigh in both studies. The studies showed that the diazepam autoinjector produced consistent plasma diazepam levels, with a rapid onset of absorption. The diazepam 10-mg autoinjector given intramuscularly was bioequivalent to a conventional syringe containing diazepam 10 mg. A single (10-mg) autoinjector and 2 (20-mg) diazepam autoinjectors administered simultaneously produced plasma diazepam concentrations that were essentially dose proportional.