J Clin Pharmacol
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Sign In to gain access to subscriptions and/or personal tools.
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kovacs, J. L.
Right arrow Articles by Butler, B.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Kovacs, J. L.
Right arrow Articles by Butler, B.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

False-Positive Urine Protein Reaction with Cibenzoline, a New Antiarrhythmic Agent

John L. Kovacs M.S.1, Ilhan Tuzel M.D.1, Keiko Aogaichi M.D.1, James J. Heger M.D.1, Linda Richmond 1, John C. Somberg M.D.1, and Brenda Butler B.A.1

1 Nutley, N.J., Indianapolis,Ind.,and Bronx, N.Y.

Following treatment with cibenzoline,a new antiarrhythmic agent, 23 of 53 patients showed positive proteinuria reactions. In all cases, these results were obtained with bromphenol reagent strips. Subsequent exposure of serial dilutions of cibenzoline to these reagent strips showed positive protein reactions at concentrations as low as 1 mg/mI. Treatment of these same solutions with acetic acid-sodium acetate heat coagulation technique produced negative findings. Specimens from 14 of the above patients were then retested employing both techniques, and in all cases the reagent strips produced positive results while the heat coagulation technique (or sulfosalicylic acid) produced negative results. Therefore, it appears that cibenzoline produces false-positive proteinuria results when bromphenol reagent strips are employed for analysis

.

Note:

The technical assistance of Dr. A. E. Burk hardt(Miles Laboratories, Ames Division,Elkhart,Ind.) and Dr. J. W. Tilley (Hoffmann-La Roche Inc., Nutley, N.J.) is greatly appreciated.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1984 by the American College of Clinical Pharmacology